Skip to main content

Usable floor area: what counts and what does not

Usable floor area is the gross floor area less the walls. Balconies and loggias do not count, basement storage probably not; in attics the 1.90 m line counts.

Citește în română

The definition sits in annex 1 of the Housing Law, no. 114/1996: usable floor area (suprafață utilă) is suprafața desfășurată, mai puțin suprafața aferentă pereților (the floor area less the area taken by the walls). For a home, you add up the usable area of every room, including bathrooms, kitchen, storage rooms and hallways. Balconies, loggias, door thresholds and radiator niches do not count. Legea 169/2026 adds a rule for attics: the clear height of the surfaces considered usable is 1.90 m.

What counts and what does not

SpaceCounts towards usable area?Where it is written
Living room, bedroomsYesLegea 114/1996, annex 1
Bathrooms, WC, shower, kitchenYesannex 1
Storage rooms, pantries and hallways inside the homeYes, as spații de depozitare și de circulație din interiorul locuinței (storage and circulation space inside the home)annex 1
Balcony and loggiaNoannex 1
Thresholds of doorways and of passages up to 1.00 m wideNoannex 1
Radiator nichesNoannex 1
Space taken by stoves and bath boilers, where heating is by stovesNo, 0.50 sq m for eachannex 1
The internal staircase of a duplexNo, except the landingsannex 1
Basement storage unit, a cellar outside the homeOur reading: no, because it is not inside the homeannex 1
AtticOur reading: only the part with a clear height of at least 1.90 mLegea 169/2026, annex 1

The “counts” list stops at what is inside the home. For anything outside it the law has no separate rule, and basement storage appears in one sentence only, about a different area, explained below.

Does the balcony count in the usable floor area?

No. Annex 1 to the Housing Law (no. 114/1996) lists balconies and loggias, together with door thresholds and radiator niches, among the spaces that do not count in the usable floor area. Only the rooms and spaces inside the home are added up.

Usable, habitable, built: three different figures

The same annex defines three areas, and property listings often mix them up.

  • Habitable area (suprafață locuibilă) is the floor area of the habitable rooms: bedrooms and living room only. It is the smallest of the three.
  • Usable area adds the kitchen, bathrooms, hallways and indoor storage.
  • Built area per dwelling (suprafață construită pe locuință) adds to the usable area the loggias and balconies, the share of the building’s common parts (laundries, drying rooms, stairwell, lift shaft, waste rooms) and the home’s internal and external walls. Here the annex says expressly that it does not include suprafețele aferente boxelor de la subsol și ale garajelor care pot fi prevăzute distinct (the area of basement storage units and of garages, which may be provided separately).

The building’s built area, used for the plot occupancy percentage, and its total built floor area, used for the land use coefficient, are different notions, defined in the Urban Planning Code and explained on the page about POT, CUT and UTR.

Can you work out usable area from built area?

The law gives no coefficient. Anyone who tells you usable area is “80% of built area” is using a rule of thumb, not a legal rule, and the result depends on wall thickness, how many balconies the flat has and how much of the stairwell is allotted to it.

The only benchmark in the law is the table of minimum areas in the same annex 1, which gives a usable and a built area for each type of home. The ratio between them comes out, row by row, between 63.8% and 64.7%. But it is only the ratio between two minimums: a real home, with thinner walls or no balcony, comes out differently. For the exact figure, measure each room at the inner face of its walls and add them up.

The attic: the 1.90 m rule

Annex 1 of Legea 169/2026 defines the attic (mansardă) and says: Înălțimea liberă a suprafețelor considerate utile ale mansardei este de 1,90 m, determinând și calculul suprafeței utile a mansardei (the clear height of the attic surfaces considered usable is 1.90 m, which also determines how the attic’s usable area is calculated). Our reading: the part under the roof lower than 1.90 m does not count towards the attic’s usable area, even if you use it for storage.

The same definition adds that the attic counts as a storey and that its usable floor area counts towards the land use coefficient (CUT). What that means when you convert a loft is explained in converting the loft.

The Housing Law has a separate height rule: habitable rooms have a minimum clear height of 2.55 m, cu excepția mansardelor, supantelor și nișelor, la care se va asigura un volum minim de 15 mc de persoană (except attics, mezzanines and niches, where a minimum volume of 15 cubic metres per person must be provided).

The minimums for a new home

Article 3 of Legea 114/1996 says that permits for new homes, indiferent de natura proprietății sau a amplasamentului (whatever the ownership or location), are granted on the basis of the minimum standards in annex 1. The table of minimum areas reads:

RoomsPersonsMinimum usable areaBuilt area per dwelling
1137 sq m58 sq m
2252 sq m81 sq m
3366 sq m102 sq m
3474 sq m115 sq m
4587 sq m135 sq m
4693 sq m144 sq m
57107 sq m166 sq m
58110 sq m171 sq m

The annex states that the number of persons is used when allocating social, emergency, service and necessity housing, and that built areas may deviate by ±10% depending on the site. For a privately built new home, the table does not say which row applies: for 3, 4 and 5 rooms it has two rows each, differing only in the number of persons. A design close to the minimum is safer if it meets the row with more persons, which asks for the larger area.

The hygiene norms approved by Order 119/2014 add three design minimums: a room of at least 12 sq m, a kitchen of at least 5 sq m and a ceiling height of 2.55 m (article 17(1)). For blocks of flats, the Code asks for documentation on hygiene norms in the permit file, which also covers asigurarea suprafețelor și înălțimilor minime normate (meeting the minimum standard areas and heights; article 265(3)(b)).

Where you need the figure

In the permit file, usable area is one of the three columns of the area table in the technical annex to the application, next to built and total floor area. At completion, the same figure matters for the energy certificate: a detached building with less than 50 sq m of usable area is not subject to the minimum energy performance requirements of Legea 372/2005, and its certificate may be drawn up only at the owner’s written and justified request.

How to fill in the table is in the technical annex: the area table, and the certificate rule in the energy certificate at handover.

When buying, ask the seller whether the figure in the listing is the habitable, usable or built area, and ask for the floor plan with the area of each room.


This article is analysis, not legal advice. The definitions and minimums cited are from Legea 114/1996, republished in Monitorul Oficial no. 393 of 31 December 1997 (consolidated form of 30 July 2022), from the norms approved by Order 119/2014 of the Minister of Health (consolidated form of 5 May 2026), from Legea 169/2026, published in Monitorul Oficial no. 661 of 10 August 2026, and from Legea 372/2005. Romanian legal terms are kept in the original where the English would be misleading. Check your own situation with the issuing authority.

AutoRize Team

The AutoRize team

We write about construction permitting in Romania: what has changed, what it means for your file and what to do now.

Your certificat de urbanism file, in 30 seconds

AutoRize generates the application, the memoriu de prezentare and the opis for the certificat de urbanism, matched to local planning rules.

Get started